Category 6 U/UTP Plug & Socket Type Patch Cord

Category 6 U/UTP Plug & Socket Type Patch Cord

Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug type on one end & socket type at the other. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx) applications support. This is fully backward compatible to Category 5e (Class D) products_backup. Each patch cord is tested with Fluke tester and individual cover include with the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

Norden Category 6 UTP patch cords are manufactured using high quality unshielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug type on one end & socket type at the other. This patch cord when used with high performance Norden Category 6 connectivity (solid UTP cable patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx) applications support. This is fully backward compatible to Category 5e (Class D) products_backup. Each patch cord is tested with Fluke tester and individual cover include with the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.

COMPLIANCE

IEEE 802.af and IEEE 802.3at for PoE Applications
ANSI/TIA-568.2-D and ISO/IEC-11801 (2nd Edition),
IEC 61156-2,EN 50173; EN 50288-6-2 Category 6 standard

DESIGN & MATERIALS

Basic Cable Conductor

Stranded Bare Annealed Copper

Wire Insulation

SFS PE

Number Of Insulated Conductors

8

Colour Code Of Pairs

Blue x White, Orange x White, Green x White, Brown x White

Individual Pair Shield

Nil

Overall Shield

Nil

Drain Wire

None

Outer Jacket And Boots

LSZH Low Smoke Zero Halogen or PVC

Jacket And Boot Colour

Per requirement

Standard Surface Marking

Includes Norden P/N, cable description

Cable O.D.

5.7 ± 0.2 mm

Bend Radius

> 23 mm without load

Storage Temperature

-20 °C to +80 °C

Temperature Operating Range

-20 °C to +75 °C

Flame Test

IEC 60332-1

Halogen Content In LSZH Cables

Null

Wire Scheme

T568B

ELECTRICAL DATA

Impedance @ 1-100 MHz

100 ±15 Ω

Impedance @ 100-250 MHz

100 ±15 Ω

Conductor Resistance

< 73 Ω/km

Contact Resistance

20 MΩ max.

Resistance Unbalance

2 % max.

Voltage Rating

72 V dc

Dielectric Strength

1 KV/min. rms

Ampacity

1.0 Amps max.

Insulation Resistance

150 MΩ/Km

Transfer Impedance

N/A

Pair to Ground Capacitance Unbalance

3.3 nF/Km nom.

MECHANICAL & TRANSMISSION DATA

Cable To Plug Tensile Strength

96N min.

Pulling Force

10 N max.

Durability

1000 Mating Cycles

Propagation Delay 1-250MHz

< 25 ns/100m

MECHANICAL & TRANSMISSION DATA

Freq.
MHz
NEXT(dB) min. RL(dB) min.
2m cord 5m cord 10m cord
1 68.0 68.0 68.0 20.0
4 65.0 65.0 65.0 21.8
10 64.8 64.2 62.8 22.5
20 60.9 58.6 57.2 23.4
30 56.2 54.9 53.6 23.0
60 50.4 49.2 48.1 20.0
100 46.4 45.3 44.4 18.0
125 44.5 43.5 42.7 17.0
150 43.2 42.2 41.1 16.2
200 40.8 39.6 39.1 15.0
250 38.8 37.9 37.6 13.8
Part Number Description Length

127-B1105X

Cat 6 U/UTP Plug & Socket Type Patch Cord PVC 05m

5m