MAXPOWER PRO is a small to medium power transformer-less UPS of CellNor. This UPS has a high output power factor at 0.9PF and a wide input voltage range 110~286Vac. The CN6006MPI, CN6006MPE model support economic (ECO) operation mode.
MAXPOWER PRO is a small to medium power transformer-less UPS of CellNor. This UPS has a high output power factor
at 0.9PF and a wide input voltage range 110~286Vac. The CN6006MPI, CN6006MPE model support economic (ECO)
operation mode.
GENERAL FEATURES
N+X parallel redundancy, support maximum 4 unit in parallel
Online double conversion with full digital control
Selectable output voltage:220/230/240VacOnline double conversion with full digital control
Wide input voltage range:110~286Vac
Maximum charging current up to 10A
Optimization battery group, the quantity of battery: 16/18/20Pcs (Settable)
ECO mode operation for energy saving
Multiple communication interface:RS232
(USB/Dry contact/SNMP card optional)Maximum charging current up to 10A
Self-testing when UPS start-up
Generator compatible
Model | CN6006MPI, CN6006MPE | ||
Capacity | VA | 6000 | |
Watts | 5400 | ||
Input | Normal Voltage | 220/230/240Vac(L+N+PE) | |
Operating Voltage Range | 110~286Vac | ||
Operating Frequency Range | 40~70Hz (50/60Hz Auto-Sensing) | ||
Power Factor | ≥0.99 | ||
Bypass voltage range | Max.voltage:230~264Vac Min.voltage:176~220Vac | ||
ECO range | Same as the bypass | ||
Harmonic distortion (THDi) | ≤5%(100% linear load) | ||
Generator input | Support | ||
Output | Output voltage | 220/230/240Vac | |
Power factor | 0.9 | ||
Voltage Regulation | ±1% | ||
Frequency | Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional) | |
Bat. mode | 50/60(±0.1)Hz | ||
Crest Factor | 3:1 | ||
Harmonic Distortion (THDv) | ≤2% with linear load, ≤5% with non-linear load | ||
Efficiency | >93.5% | ||
Battery | Battery voltage | 192/216/240Vdc (Adjustable) with Neutral, (Standard unit 240Vdc) | |
Capacity (Standard unit) | 9Ah/12V (7Ah/12V optional) | ||
Typical recharging time | 6~8 hours (to 90% of full capacity) | ||
Charging current | 1A(Standard unit); Long run unit Max.current 10A(charging current can be set according to battery capacity installed) | ||
System | Transfer time | Mains to battery:0ms; Mains to bypass:0ms | |
Overload | Line mode | Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% turn to bypass mode immediately | |
Bypass mode | 40A(Breaker) | ||
Short circuit | Hold whole system | ||
Overheat | Line mode: Turn to bypass; Backup mode: shut down UPS immediately | ||
Battery low | Alarm and switch off | ||
Self-diagnostics | Upon power on and software control | ||
Battery | Advanced battery management | ||
Audible & Visual alarms | Line failure, Battery under voltage, Overload, System fault | ||
LED & LCD display | Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS Fault | ||
LCD display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage,
Inner temperature & Remaining battery backup time | ||
Communication interface | RS232, USB,SNMP card(optional), Parallel card(optional), Relay card (optional) | ||
Environment | Operating temperature | 0~40°C | |
Storage temperature | -25~55°C | ||
Humidity range | 0~95% (Non-condensing) | ||
Altitude | <1500m | ||
Noise level | <55dB | ||
Standards | Safety | IEC/EN62040-1,IEC/EN62477-1 | |
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | ||
Physical | Dimension | I:191 x 460 x 720 E:191 x 460 x 337 | |
Net Weight (kg) | 69 12 |
EXTERNAL BATTERY PACK
MODEL | CNBC06120CR | ||
BATTERY SYSTEM | |||
Battery type | VRLA (Lead acid maintenance free battery) | ||
Typical battery recharging time | 6~8 hours (to 90% of full capacity) | ||
Typical battery life | 3~5 years, depend on discharging cycle and ambient temperature | ||
System voltage | ±120Vdc | ||
Battery quantity | 2*±10 Pcs | ||
Capacity | 7Ah/9Ah (12V) | ||
Backup time @ 50% load | 43 minutes | ||
Backup time @ 100% load | 15 minutes | ||
PHYSICAL | |||
Dimension W x D x H (mm) | 250 x 597 x 616 | ||
Net weight (kg) | 122/134 | ||
ENVIRONMENT | |||
Safety | CE | ||
Operating environment | 0°C~40°C | ||
Relative humidity | 0~95% (Non condensing) | ||
Noise level | <40dB at 1 Meter |
Part Number | Description | ||
CN6006MPI | 6kVA Medium Power Transformerless UPS (internal battery) | ||
CN6006MPE | 6kVA Medium Power Transformerless UPS (external battery) | ||
CNBN06120CT | 120 VDC Battery Pack |