• Call: +44 (0) 1255 474063
Quick Support

Max Power Series

Overview

MAXPOWER Series (short version) is a small to medium power transformer-less UPS of CellNor. This series is the classic
product of CellNor. It releases very early and designs with high standard; This series is improved continually combined with
customers’ application feedback, and it became a very cost-effective product series. This product series has a very good
sale performance, and received highly praises from customers. The categories of this UPS are abundant, and the product is
stable and reliable, it can meet the demands of small to medium power UPS of customers.

Specification

GENERAL FEATURES

  • Rack-Tower convertible

  • Two directions LCD display

  • Online double conversion (PFC)

  • Full digital control

  • Output power factor: 0.9

  • Economic operation mode (ECO)

  • Wide input voltage range

  • Self-testing when UPS startup

  • Self-testing when UPS startup

  • Cold star

  • Multi functional protection

  • Output bypass can be set

  • Input L and N reversed alarm function

  • Optimized battery con?guration(1k:24Vdc,
    2k:48Vdc, 3k:72Vdc)

  • Charger can be extended

  • Diverse options of accessories, intelligent
    management

  • Intelligent slot optional: SNMP/Dry contact card

Model CN5001MEI-RM/CN5001MEE-RM CN5002MEI-RM/CN5002MEE-RM CN5003MEI-RM/CN5003MEE-RM

Capacity

VA

1000

2000

3000

Watts

900

1800

2700

Phase

Single phase with ground

Input

Nominal Voltage

200/208/220/230/240Vac

Input Voltage Range

110~300Vac @ 60% load, 160~300Vac @ 100% load

Frequency Range

45~55Hz/55~65Hz(Auto-detect)

Power Factor

≥0.99 @Nominal voltage(100% load)

Output

Output Voltage

200/208/220/230/240Vac

Power Factor

0.9

Voltage Regulation

±1%

Frequency range (Synchronized range)

45~55Hz/56~64Hz

Frequency range (Batt.mode)

50Hz/60Hz±0.1Hz

Current crest ratio

3:1

Harmonic Distortion (THDv)

≤3% THD(Linear load)

≤6% THD(Non-linear load)

Transfer Time

AC to DC

Zero

Inverter to Bypass

4ms(Typical)

Waveform 

Pure Sinewave

Efficiency

AC Mode

88%

89%

90%

Battery Mode

83%

85%

86%

Battery

Standard
Model

Battery Type

12V/9AH

Numbers

2

4/6

6

Backup time

Estimated remaining time displayed on the LCD

Typical Recharging Time

4 hours recover to 90% capacity

Charging current(max.)

1.0A

Charging Voltage

27.4Vdc±1%

54.7Vdc±1% /82.1Vdc±1%

82.1Vdc±1%

Long-run
Model

Battery numbers

Depending on the capacity of external batteries

Charging current(max.)

6A/12A(Double board

6A/12A(Double board

6A/12A(Double board)

Charging Voltage

27.4Vdc±1%

54.7Vdc±1% / 82.1Vdc±1%

82.1Vdc±1%

Indicators

LCD 

Load level, Battery level, AC mode, Battery mode, Bypass mode and Fault indicators

Alarm

Battery Mode

Beeps every 4 seconds

Battery Low

Beeps every second

Overload

Beeps twice per second

Fault

Continously beeping

Environment

Humidity

20-90% RH @ 0-40°C (Non-condensing)

Noise Level

<50dB @ 1 Meter

Physical

Dimension

Standard model

380×440×86.5

520×440×131

Long run model

380×440×86.5

520×440×131

Weight

Standard model

12

21.5 / 26.5

26

Long run model

7

11.5

11.7

Management

Smart RS232/USB

Supports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux, FreeBSD and MAC Optional

Optional SNMP

Power management from SNMP manager and web browser

Specifications are subject to change without prior notice

Model CNBC106MR CNBC107MR CNBC107MR

Capacity

VA

24

48

72

Watts

9

9

9

Input

Voltage

150~285Vac or 80~145Vac

Phase

Single phase with ground

Output

Output Voltage

(27.4±1)Vdc

(54.8±1)Vdc

(82.2±1)Vdc

Charging mode

CV mode

Charging current(Max)

1.4A

Leakage current

<100uA

Phase

Single phase with battery ground

Battery

Number of batteries per set 

2

4

6

Number of batteries set

2

Battery type

12V/9Ah

Backup time

In accordance with the battery capacity and load

Typical recharging time

In accordance with the battery capacity

Rated battery voltage

24VDC

48VDC

72VDC

Battery current protection

60A fast fuse

Replace

Hot swappable

Environment

Safety

CE

Operating environment

0~40°C

Relative humidity

0~90% (Non-condensing)

Noise level

<[email protected] 1Meter

Physical

Battery socket

Anderson like power pole modular connec tors

Dimension

380×440×86.5

520×440×131

Net weight

TB

 

STANDARDS      

 

Input socket

IEC320 C13-10A

AC power cord

IEC320 C14-10A

                                                                      

Ordering Information

Part Number Description

CN7001MPI-RM

1kVA Medium Power Transformerless UPS (Internal battery) Rack Moun

CN7001MPE-RM

1kVA Medium Power Transformerless UPS (External battery) Rack Mount

CN7011MPI-RM

1.5kVA Medium Power Transformerless UPS (Internal battery) Rack Mount

CN7011MPE-RM

1.5kVA Medium Power Transformerless UPS (External battery) Rack Mount

CN7002MPI-RM

2kVA Medium Power Transformerless UPS (Internal battery) Rack Mount

CN7002MPE-RM

2kVA Medium Power Transformerless UPS (External battery) Rack Mount

CNBC106MR

24VDC Battery Pack

CNBC107MR

48VDC Battery Pack

CNBC108MR

72VDC Battery Pack

Downloads

DataSheet PDF 201.45KB DOWNLOAD

INTERESTED IN OUR PRODUCT RANGE?