• Call: +44 (0) 1255 474063
Quick Support

Nex Power Series

Overview

Nexpower Series is a small to medium power transformer-less UPS of CellNor. Nexpower adopts new circuit design, and
electrical performance is optimized. The series is with reasonable inside arrangement, the dimension of the unit is small
and t he power density is high. The appearance is simple and beautiful by new design. Advanced design makes Nexpower
more reliable and high power efficient, and reduce the TCO (total cost ownership) in result. Miniaturization design reduces
the transportation space and installation space, and this also make it easy to maintain the Nexpower for customers.
Nexpower Series can support lithium battery and this supplies more choices to customers.

Specification

 

GENERAL FEATURES

  • N+X parallel redundancy

  • Online double conversion with DSP control

  • Input current harmonic: <3%

  • Optimization battery group, the quantity of
    battery:16/18/20 pieces(optional)

  • Output power factor at 0.9PF

  • Wide input voltage range: 120~276Vac

  • Wide input frequency range

  • Support generator input

  • ECO mode operation for energy saving

  • Self-testing when UPS startup

  • Options: SNMP card/Relay card/ Parallel card

  • Cold start

Model CN6310OI CN6310OE CN6315OI CN6315OE CN6320OI CN6320OE

Capacity

VA

10

10

15

15

20

20

Watts

9

9

13.5

13.5

18

18

Input

Normal Voltage

220/230/240Vac

Operating Voltage Range

120~276Vac

Frequency Range

50Hz:45~55Hz; 60Hz:54~66Hz(auto sensing)

Power Factor

≥0.99 

Bypass voltage range

Max.voltage: 220V: +25%(optional +10%,+15%,+20% )
230V: +20% (optional +10%,+15%)
240V: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)

Bypass frequency range

Frequency protection range:±10

ECO range

Same as the bypass

Harmonic distortion (THDi)

<3%(100% linear load)

Generator input

Support

Output

Output voltage

220/230/240Vac

Power factor

0.9

Voltage Regulation

±1%

Frequency

Line mode

±1%/±2%/±4%/±5%/±10% of the rated frequenc y(optional)

Bat. mode

(50/60±0.1)Hz

Crest Factor

3:1

Harmonic Distortion (THDv)

≤2% with linear load, ≤5% with non-linear load

Efficiency

>93.%

Battery

Battery voltage

±96/108/120Vdc (optional)

Capacity (standard unit)

12V-7Ah/9Ah

Typical recharging time

6~8 hours (to 90% of full capacity)

Charging current

1A(Standard unit); Long run unit Max.current10A(charging current can be set according to battery capacity installed)

System
Features

Transfer time

Mains to battery:0ms; Mains to bypass:0ms

Overload

Line mode

Load≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min, >150% tur n to bypass mode immediately

Bypass mode

63A(Breaker)

Short circuit

Hold whole system

Overheat

Line Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediately

Battery low

Alarm and switch off

Self-diagnostics

Upon power on and software control

Battery

Advanced battery management

Audible & Visual alarms

Line failure, Battery under voltage, Overload, System fault

LED & LCD display

Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload & UPS fault

LCD display

Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage,
Inner temperature & Remaining battery backup time

Communication interface

RS232,USB,SNMP card(optional), Parallel card(optional), Relay card (optional)

Environment

Operating temperature

0~40°C

Storage temperature

-25~55°C

Humidity range

0~95% (Non-condensing)

Altitude

<1500m

Noise level

<55dB

Physical

Dimension W×D×H (mm)

Standard model: 250x710x810 ; long run model: 220x535x435

Net weight (kg)

Standard model: 98kg ; long run model: 27kg

 

 
STANDARDS      

 

Safety

IEC/EN62040-1,IEC/EN60950-1

EMC

IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8

                                                                      

Ordering Information

Part Number Description

CN6310OI

10kVA Online Transformerless UPS (Inetrnal battery) 3:1 Phase

CN6310OE

10kVA Online Transformerless UPS (External battery) 3:1 Phase

CN6315OI

15kVA Online Transformerless UPS (Inetrnal battery)

CN6315OE

15kVA Online Transformerless UPS (External battery)

CN6320OI

20kVA Online Transformerless UPS (Inetrnal battery)

CN6320OE

20kVA Online Transformerless UPS (External battery)

Downloads

DataSheet PDF 174.95KB DOWNLOAD

INTERESTED IN OUR PRODUCT RANGE?