3 CORE 22 AWG SHIELDED MULTI-CONDUCTOR CABLE

The Shielded Multi Conductor Cable from NORDEN is suitable to use within Audio, Control, and Instrumentation purposes. The cable is constructed with PE Insulation, Aluminium Foil – Polyester Tape Shielded and FRNC Outer jacket.

CABLE CONSTRUCTION


PHYSICAL CHARACTERISTICS

CharacteristicValue

No. of Conductor

3

Conductor Size

22 AWG 7 x 0.2 mm

Insulation Diameter 
1.2 ± 0.05 mm
Drain Wire Size
7 X 0.2 mm
Jacket Thickness 
0.45 mm

Nom.Outer Jacket Diameter

3.6 ± 0.3 mm

Max. Recommended Pulling Tension

12 KGS

Min. Bend Radius 
10 X OD 

Operating Temperature

-20°C ~ +60°C

 


ELECTRICAL CHARACTERISTICS

CharacteristicUnitValue

Nom. Conductor DCR

Ω/km

53.5

Nom. Capacitance Cond. to Cond. 
pF/m
50
Nom. Capacitance Cond. to Cond. & Shield
pF/m 
100
Nom. Characteristic Impedance
Ω
90
Max. Recommended Current @ 25°C
A2.5
Max. Operating Voltage UL
V
300
Sparker Test
VAC
3000

MECHANICAL CHARACTERISTICS

CharacteristicValue

Test Material

FRNC

Before Tensile Strength (Mpa)

13.8

Aging Elongation (%)

100

After Tensile Strength (Mpa)

11.8

Aging Elongation (% ) 
50% 

Cold Bend (-20±°C x 4 hrs)

No Crack

INSULATION COLOUR CODE

Individual PairColour
Core 1
Black 
Core 2
White
Core 3
Red
Part NumberDescription
71-3203229