SINGLE CORE -SINGLE INSULATED XL-HFFR FIRE RESISTANT POWER CABLE

Norden single-core single insulated XL-HFFR fire-resistant power cable can be used in cable wiring systems that require improved fire performance and circuit integrity. These cables are mainly used in installations where a fire situation may pose a major hazard (trunking and conduits). The Fire-resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning.

Norden single-core single insulated XL-HFFR fire-resistant power cable can be used in cable wiring systems that require improved fire performance and circuit integrity. These cables are mainly used in installations where a fire situation may pose a major hazard (trunking and conduits). The Fire-resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. 

CABLE CONSTRUCTION

Conductor

Stranded Annealed Copper

(IEC/BS/EN 60228 - Class 2)

Fire Barrier

Mica Tape

Insulation      

XL-HFFR

STANDARD COMPLIANCE:

  • BS EN 50363-5
  • EC 60332-1-2
  • IEC 60331-21, EN 50200 PH120, BS 6387 CWZ
  • IEC 61034-1/2
  • IEC 60754-1/2 

ELECTRICAL & MECHANICAL CHARACTERISTICS

PropertiesValue
1.5 mm² - 10 mm²
16 mm² - 300 mm²
Operating Voltage 
450/750V

Test Voltage
2500 V
3500 V
Insulation Resistance
min. 4000 MΩ.km
Operation Temperature
30°C to + 90°C
Min. Bending Radius8 x D

PHYSICAL INFORMATION

Nom. Cond.
Cross-Sect. mm²
Insulation Thickness(mm) 
Cable Diameter
mm (±5 %)
Max. Conductor Resistance[Ω/km] 
Copper Weight [kg/km] 
Cable Weight [kg/km] 
1x1.5 mm²
0.7
3.90
12.1
13.4
27.2
1x2.5 mm²
0.8
4.50
7.14
21.5
39.4
1x4 mm² 
0.8
5.00
4.61
34.4
55.1
1x6 mm²
0.8
5.60
3.08 
51.6
75.5 
1x10 mm²
1.0
6.70
1.83
92.8
126.4
1x16 mm² 
1.0
7.60
1.15
140.0
179.8
1x25 mm² 
1.2 
9.30
0.727
220.6
281.8
1x35 mm²
1.2 
10.30
0.524
300.0 
369.3
1x50 mm²
1.4
11.80
0.387 
407.0
505.5
1x70 mm² 
1.4
13.90
0.268
605.5
706.0
1x95 mm² 
1.6 
15.50
0.193
856.2
980.9 
1x120 mm² 
1.6 
18.10
0.153 
1056.3
1204.1 
1x150 mm²
1.8
19.00
0.124
131.8
1486.8
1x185 mm²
2.0
21.30
0.0991
1572.0
1856.6
1x240 mm² 
2.2 
24.40
0.0754
2061.0
2323.8
1x300 mm²
2.4
26.80
0.0601 
2600.0 
3212.4
Part NumberDescription
6G-1501X1 Core 1.5 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-2501X
1 Core 2.5 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR 
6G-4001X
1 Core 4 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-6001X 
1 Core 6 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR 
6G-1001X
1 Core 10 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-1601X
1 Core 16 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-2001X
1 Core 25 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-3501X 
1 Core 35 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-5001X1 Core 50 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-7001X
1 Core 70 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-9501X 
1 Core 95 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-0A01X
1 Core 120 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-0B01X
1 Core 150 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-0C01X
1 Core 185 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR
6G-0D01X
1 Core 240 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR 
6G-0E01X
1 Core 300 Sq.mm Single Core -Single insulated Fire-Resistant Power Cable XL-HFFR

X > RD:Red OR:Orange BL:Blue BK:Black