CATEGORY 5E F/UTP DOUBLE JACKET CABLE

Norden Category 5e Double jacket cables exceed Category 5e / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications up to 100m. Norden Category 5e D/J cables used in digital distribution frames in transmission stations, fixed & portable indoor applications, harsh environmental outdoor applications with UV rated FR PVC outer Jacket.

Norden Category 5e Double jacket cables exceed Category 5e / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications up to 100m. Norden Category 5e D/J cables used in digital distribution frames in transmission stations, fixed & portable indoor applications, harsh environmental outdoor applications with UV rated FR PVC outer Jacket.



PRODUCT CLASSIFICATION


Product SequencePremium
Product TypeTwisted Pair Cable


MATERIAL CONSTRUCTION & DESIGN


Conductor MaterialBare Copper
Conductor Size0.51 mm, 24 AWG
Conductor ConstructionSolid
Insulation MaterialHigh Density PE
Insulation Diameter1.03±0.2 mm
Ind.Shield Material
Aluminium Foil
Rip Cord
Yes
Drain Wire
Yes
Drain Wire Material & Thickness
Tinned copper 0.45 mm
Conductor Unit Identification
Solid/stripe
Colour Code
Per TIA/EIA 568-B 
Total Number of Wires
8
Inner Jacket & Thickness 
FR PVC / PVC, 0.55±0.2 mm
Outer Jacket
FR PVC/PE
Outer Jacket Thickness & Ex. Diameter0.60±0.01 mm, 7.5±0.5 mm
Outer Jacket ColourPer Requirement 
Marking
Per Requirement 


 ELECTRICAL & MECHANICAL CHARACTERISTICS


Frequency Range1 - 100 MHz
Impedance100 Ω ±15
Coupling Attenuation40 dB min @ 30-100 MHz
Max. Dc Resistance93 Ω/km @ 20 °C
Max. Resistance Unbalance5 %
Capacitance5.6 nF/100m max.
Capacitance Unbalance1.7 pF/m max.
Velocity Of Propagation69 %
Propagation Delay Skew25 ns/100m max.
Dielectric Strength1 KV/minute
Min. Insulation Resistance5 GΩ•km
Max. Tensile Strength - Short Term110 N
Min. Bend Radius60 mm
Operating Temperature Range-30 °C +60 °C


TRANSMISSION PERFORMANCE

Cat. 5e Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ELFEXT
dB
PSELFEXT
dB
11.873.871.825.078.876.8
43.664.862.828.066.864.8
105.855.353.328.058.856.8
208.353.852.828.052.850.8
31.2510.550.948.127.850.048.3
62.515.346.444.626.143.041.4

*Supplied cables meets Cat. 5e min. transmission requirements of IEC 61156-5 Ed. 2

Part NumberDescriptionStandard Length
112-21254204X
Category 5e F/UTP 4 Pair D/J Cable FR PVC/ FR PVC
500 mtr
112-21213204X
Category 5e F/UTP 4 Pair D/J Cable PVC/ PE
500 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)