Fill out your details and our executive will get in touch with you soon.
The UL listed FPLR type shielded power limited fire alarm riser cable from Norden is suitable to be use in a vertical runs in signaling & fire alarm system. It works in high temperature levels. This cable is constructed with FR-PVC insulation and outer jacket with aluminum and PE tape shielding that meets UL 1666 specifications. This cable complies with VW - 1 Flame Test requirements in ANSI/UL 1581.Tested as per ANSI/UL 1666 for flame propagation height of electrical and optical - Fibre Cables Installed Vertically in Shafts.
The UL listed FPLR type shielded power limited fire alarm
riser cable from Norden is suitable to be use in a vertical runs
in signaling & fire alarm system. It works in high temperature
levels. This cable is constructed with FR-PVC insulation and
outer jacket with aluminum and PE tape shielding that meets
UL 1666 specifications. This cable complies with VW - 1
Flame Test requirements in ANSI/UL 1581.Tested as per
ANSI/UL 1666 for flame propagation height of electrical and
optical - Fibre Cables Installed Vertically in Shafts.
Standard
CABLE CONSTRUCTION
Core | Colour |
2 Core | Blue/Brown |
3 Core | Blue/Brown/Black |
4 Core | Blue/Brown/Black/Grey |
5 Core | Blue/Brwon/Black/Grey/Red |
6 Core | Black/Red/White/Green/Blue/Yellow |
7 Core | Black/Red/White/Green/Blue/Yellow/Orange |
No. of Cores/Cross-Section (mm2) |
Max.Conductor Resistant @20°C (Ω/km) | Conductor diameter, mm (±0.005) |
Insulation diameter mm (±0.05) |
Jacket diameter, mm (±0.1) |
2 x 1.0 | 18.1 | 1.12 | 1.95 | 5.8 |
2 x 1.5 | 12.1 | 1.29 | 2.35 | 6.6 |
2 x 2.5 | 7.4 | 1.76 | 2.75 | 7.4 |
2 x 3.5 | 5.22 | 2.11 | 3.21 | 8.1 |
2 x 4.0 | 4.61 | 2.25 | 3.35 | 8.6 |
2 x 6.0 | 3.08 | 2.76 | 3.86 | 9.7 |
3 x 1.0 | 18.1 | 1.12 | 1.95 | 6.1 |
3 x 1.5 | 12.1 | 1.36 | 2.35 | 7.0 |
3 x 2.5 | 7.4 | 1.76 | 2.75 | 8.1 |
3 x 4.0 | 4.61 | 2.25 | 3.35 | 9.0 |
4 x 1.0 | 18.1 | 1.12 | 1.95 | 7.0 |
4 x 1.5 | 12.1 | 1.36 | 2.35 | 7.6 |
4 x 2.5 | 7.4 | 1.76 | 2.75 | 9.1 |
4 x 4.0 | 4.61 | 2.25 | 3.35 | 10.5 |
5 x 1.5 | 12.1 | 1.36 | 2.35 | 8.7 |
6 x 2.5 | 7.5 | 1.76 | 2.75 | 10.5 |
7 x 1.5 | 12.1 | 1.36 | 2.35 | 9.9 |
PART NUMBER | DESCRIPTION |
52-1002XY | |
52-1502XY | FireNor FPLR Cable 2C x 1.5 mm² |
52-2502XY | FireNor FPLR Cable 2C x 2.5 mm² |
52-3502XY | FireNor FPLR Cable 2C x 3.5 mm² |
52-4002XY | FireNor FPLR Cable 2C x 4 mm² |
52-6002XY | FireNor FPLR Cable 2C x 6 mm² |
52-1003XY | FireNor FPLR Cable 3C x 1.0 mm² |
52-1503XY | FireNor FPLR Cable 3C x 1.5 mm² |
52-2503XY | FireNor FPLR Cable 3C x 2.5 mm² |
52-4003XY | FireNor FPLR Cable 3C x 4.0 mm² |
52-1004XY | FireNor FPLR Cable 4C x 1.0 mm² |
52-1504XY | FireNor FPLR Cable 4C x 1.5 mm² |
52-2504XY | FireNor FPLR Cable 4C x 2.5 mm² |
52-4004XY | FireNor FPLR Cable 4C x 4.0 mm² |
52-1505XY | FireNor FPLR Cable 5C x 1.5 mm² |
52-2506XY | FireNor FPLR Cable 6C x 2.5 mm² |
52-1507XY | FireNor FPLR Cable 7C x 1.5 mm² |
X (Colour code) > RD: Red
Y (Packing length) > 1:100mtr, 2: 500mtr