Cat 7 S/FTP 4 Pair Double Jacket External Cable

Cat 7 S/FTP 4 Pair Double Jacket External Cable

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR. It supports all Ethernet for external applications 

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR. It supports all Ethernet for external applications 



COMPLIANCE

ISO/IEC 61156-5

EN 50288-4

LSZH: IEC 60332-1, IEC 60754, IEC 6103

PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material Solid Bare Copper
Conductor Size 23 AWG
Normal Conductor Diameter 0.560±0.005 mm
Insulation Material Skin-Foam-Skin PE
Insulation O.D 1.330±0.05 mm
Conductor Unit Identification
Solid/Stripe
Color Code Per TIA/EIA 568-B
Ind. Shield Material
Aluminium/Mylar
Ind. Shield Design 100 % Coverage
Conductor Unit Lay-Up
Pairs
Overall Braid Shield Material
Tinned Copper 0.10 mm
Braid Coverage 45 %
Drain-Wire Material
N/A
Inner Jacket Material
LSZH
Outer Jacket Material LDPE
Outer jacket thickness & Ex. Diameter 0.60±0.05 mm, 8.8±0.5 mm
Rip cord Yes
Total Number of Wires 8
Outer Jacket Color Per Requirement
Marking Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Impedance 100 Ω
Max. DC Resistance(Ω/100m) 9.5Ω/km
Max. Resistance Unbalance 5 %
Capacitance Unbalance 3.3 pF/m max.
Velocity of Propagation 74 % nom
Propagation Delay Skew 25 ns/100m max.
Dielectric Strength DC 1kv,1min pass
Dielectric Strength to Shield 1.5 kV/minute
Min. Insulation Resistance 5000Ω•km
Coupling Attenuation Min 39.4dB/100M @ 600MHz
Before aging tensile strength (Mpa)
≥10%
Min. Bend Radius 80 mm
Operating Temperature Range -40 °C +60 °C

TRANSMISSION PERFORMANCE(100m)

Freq.
MHz
Attenuation dB
NEXT
dB
PSNEXT
dB
RL
dB
Phase Delay
ns
ELFEXT
dB
PSELFEXT
dB
1 - 78.0 75.0 20.0 570.0 78.0 75.0
4 3.74 78.0 75.0 23.0 552.0
78.0 75.0
8 5.24 78.0 75.0 24.5 546.7 75.9 72.9
10 5.86 78.0 75.0 25.0 545.4 74.0 71.0
16 7.41 78.0 75.0 25.0 543.0 69.9 66.9
20 8.29 78.0 75.0 25.0 542.0 68.0 65.0
25 9.29 78.0 75.0 24.3 541.2 66.0 63.0
31.25 10.41 78.0 75.0 23.6 540.4 64.1 61.1
62.5 14.88 75.5 72.5 21.5 538.6 58.1 55.1
100 19.02 72.4 69.4 20.1 537.6 54.0 55.0
150 23.56 69.8 66.8 18.9 536.9 50.2 47.2
200 27.47 67.9 64.9 18.0 536.5 48.0 45.0
250 30.97 66.4 63.4 17.3 536.3 46.0 43.0
30034.1965.262.217.3536.144.541.5
60050.1060.757.717.3535.538.435.4


Part NumberDescriptionStandard Length
115-20223504XCategory 7 S/FTP 4 Pair Double Jacket External Cable 305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)