CATEGORY 6 U/UTP EXTERNAL DOUBLE JACKET PATCH CORD - PE WITH ANTI RODENT CHEMICAL

Norden Cat 6 U/UTP External Double Jacket Patch Cord consists of PE insulated 26AWG Stranded Bare Electrolytic Grade Copper Conductors (4 pairs), separated from one another through a cross separator (which improves the Cross Talk). The cable has an inner sheath of PVC followed by an outer jacket of PE with Anti-Rodent Chemical properties. This patch cord when used with high-performance Norden Category 6 connectivity (solid UTP cable, patch panels, and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx) applications support. Each patch cord is tested with a Fluke tester

Norden Cat 6 U/UTP External Double Jacket Patch Cord consists of PE insulated 26AWG Stranded Bare Electrolytic Grade Copper Conductors (4 pairs), separated from one another through a cross separator (which improves the Cross Talk). The cable has an inner sheath of PVC followed by an outer jacket of PE with Anti-Rodent Chemical properties. This patch cord when used with high-performance Norden Category 6 connectivity (solid UTP cable, patch panels, and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx) applications support. Each patch cord is tested with a Fluke tester

COMPLIANCE

IEEE 802.af and IEEE 802.3at for PoE applications
ANSI/TIA-568.2-D and ISO/IEC-11801 (2nd Edition),
IEC 61156-2, EN 50173; EN 50288-6-2 Category 6 standard


DESIGN & MATERIALS

Basic Cable Conductor

Stranded Bare Electrolytic Grade Copper

Conductor Size 

26AWG 

Wire Insulation 

Polyethylene (HDPE)

Number Of Insulated Conductors

8

Colour Code Of Pairs

Blue x White, Orange x White, Green x White, Brown x White 

Individual Pair Shield

Nil

Overall Shield 

Nil

Drain Wire

None

Inner Sheath 

PVC

Colour of Inner Sheath 

Grey

Outer Sheath 

PE with AntiRodent 

Colour of Outer Sheath 

Black

Cable O.D. 

6.50 ± 0.30 mm

Standard Surface Marking

Includes Norden P/N, cable description 

Rip Cord 

Yes 

Cross Filler

HDPE

Operating Temperature 

-20 °C to +75 °C

Storage Temperature

-20 °C to +80 °C

Bend Radius 

> 23 mm without load

Wire Scheme

T568B 

ELECTRICAL DATA

Characteristic Impedance

100±15 Ohms

Conductor Resistance

Max. 145 Ω/km @20 C

Contact Resistance

Max. 20 MΩ

Resistance Unbalance

Max. 5 % 

Mutual Capacitance

Max. 5.6 nf/100 mtr

Pair to Ground Capacitance Unbalance 

Max. 330 pf/100 mtr

Voltage Rating 

72 VDC 

Ampacity

Max.1.0 Amps

Normal Velocity of Propagation

69%

Worst Case Cable Skew 

Max. 45 ns/100 mtr

Worst Cable Skew 

45 ns/100 mtr

Durability

1000 Mating Cycles

Propagation Delay 1-250MHz 

< 25 ns/100m

TRANSMISSION PERFORMANCE DATA

Freq.
MHz
ATT(dB/100m) max. 
NEXT(dB) min. 
PS.NEXT(dB) min. 
ACRF (dB@100m)min. 
PS.ACRF (dB@100m)min.
Return Loss (dB) min.
12.165 
62
63.3
60.3
19
446360.5
51.2
48.2
19
85.7
58.255.6
45.2
42.2
19
106.356.2
5443.3
40.3
19
16853.2
50.6
39.2
36.2
18
20951.6
49
37.2
34.2
17.5
2510.1 
50
47.3
35.3
32.3
17
31.2511.448.4
45.7
33.4
30.4
16.5
62.516.543.4
40.6
27.3
24.3
14
10021.339.9
37.1
23.3
20.3
12
20031.534.8
31.9
17.2
14.2
9
25035.933.1
30.2
15.3
12.3
8

Part NumberDescriptionLength
12R-3G101X
Cat 6 U/UTP External Double Jacket Patch Cord - PE with Anti Rodent Chemical 
1m 
12R-3G102X
Cat 6 U/UTP External Double Jacket Patch Cord - PE with Anti Rodent Chemical 
2m 
12R-3G103X
Cat 6 U/UTP External Double Jacket Patch Cord - PE with Anti Rodent Chemical
3m 
12R-3G105X
Cat 6 U/UTP External Double Jacket Patch Cord - PE with Anti Rodent Chemical
5m 
X: BK(Black)