100-200kVA Double Conversion Transformer-Based UPS

Ultra Power Series is a transformer-based UPS of Cellnor, both input and output are 3 phases. The output power factor is 0.9. These ups can work in parallel and expand its power capacity. This series UPS is highly reliable and have good impact resistance, it can supply safe and reliable protection for the load

Ultra Power Series is a transformer-based UPS of Cellnor, both input and output are 3 phases. The output power factor is 0.9. These ups can work in parallel and expand its power capacity. This series UPS is highly reliable and have good impact resistance, it can supply safe and reliable protection for the load

General Features

  • Online Double Conversion
  • Full DSP Control
  • High Power Factor
  • Wide input adaptability
  • Optimized battery management
  • N+X parallel redundancy
  • Strong overload capability
  • Multi-protection
  • 6 Pulse and 12 Pulse Rectifier (Optional)
  • EPO function

Specification

ModelCN433100TU
 CN433120TU 
 CN433160TU 
CN433200TU 

Capacity

kVA

100kVA

120kVA
160kVA
200kVA

Watts

90kW

108kW
144kW
180kW

Input

Normal Voltage380/400/415Vac (3Ph+N+PE) (-25% +20%)
Harmonic distortion(THDi) 
<3%(100% linear load)
Operating frequency range
50/60Hz (±5Hz)
Power factor
0.98 (with filter)
Bypass voltage range

Upper limit:+20%(+10%,+15%,+20% adjustable)

Lower limit:-40%(-10%,-20%,-30%,-40% adjustable)

Bypass Frequency range
±10%(±2.5%,±5%,±10%,±20% adjustable)

Output

Rated voltage380/400/415Vac (3Ph+N+PE)
Power factor
0.9
Voltage regulation
±1%
Frequency  
50/60(±0.1)Hz
Crest factor
3:1
Harmonic distortion (THDv)
≤2% with linear load
Efficiency
>92%                                                                                 >92.5%
Output Waveform
Pure SineWave

Battery

Battery voltage384Vdc (30/32/34pcs)

System Features

Transfer timeMains to battery:0ms;
Overload  
110%60min, 125%10min, 150%1min
LED Display
Input, Inverter, Bypass, Battery, Output, Status 
LCD Display
I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings
Communication
USB, RS232, RS485, Parallel port, dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional)

Environment

Operating temperature0~40°C
Storage temperature
-25~55°C
Humidity range
0~95% (Non-condensing)
Altitude
<1500m
Noise level
<65dB

Physical

Dimension WxDxH(mm)1160x805x1600 (6P)/1520x830x1600 (12P)        1200x800x1600 (6P)/1400x1000x1900 (12P)
Net Weight (kg)
800/1100903/1250980/1645
1030/1715

Standards

SafetyIEC/EN62040-1,IEC/EN60950-1
EMC

IEC/EN 62040-2;IEC 61000-2-2;IEC 61000-4-2;IEC 61000-4-3;IEC 61000-4-4

IEC 61000-4-5;IEC 61000-4-6;IEC 61000-4-8;IEC 61000-4-11

Performance
IEC62040-3


Part NumberDescription
CN433100TU100kVA Double Conversion Transformer-Based UPS Input/Output Three-Phase
CN433120TU 
120kVA Double Conversion Transformer-Based UPS Input/Output Three-Phase
CN433160TU160kVA Double Conversion Transformer-Based UPS Input/Output Three-Phase
CN433200TU200kVA Double Conversion Transformer-Based UPS Input/Output Three-Phase