Norden Category 6A S/FTP cables exceed Category 6A / ClassEA specification. It is tested to 500 MHz frequency range and designed to support 10 Gigabyte applications to full 100 m.Extremely high pair-balance providing excellent EMC (Electro Magnetic compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/FTP cabling systems. S/FTP (Twisted Pair – overall shielded and individual Foil shield) cabling systems are installed for improved Alien Cross talk performance.
Norden Category 6A S/FTP cables exceed Category 6A / Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. S/FTP (Foil Twisted Pair - Shielded) cabling systems are installed to protect data from potentially corrupting electromagnetic interference (EMI) and improved Alien Cross talk performance.
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material |
Bare Copper |
Conductor Size |
0.57 mm, 23 AWG |
Conductor Construction |
Solid |
Insulation Material |
SFS PE |
Insulation O.D. |
1.35 mm nom. |
Conductor Unit Identification |
Solid/Stripe |
Colour Code |
Per TIA/EIA 568-B |
Ind. Shield Material |
Aluminium/Polyester Foil |
Ind. Shield Design |
100 % Coverage |
Conductor Unit Lay-Up |
Pairs |
Overall Shield Design |
Braid |
Overall Shield Material |
Tinned Copper |
Braid Coverage |
More than 45 %. |
Drain-Wire Material |
N/A |
Total Number of Wires |
8 |
Outer Jacket |
LSZH (Low Smoke Zero Halogen) or PVC or Plenum PVC |
Outer Jacket Thickness & Ex. Diameter |
0.55±0.05 mm, 7.9±0.5 mm |
Outer Jacket Colour |
Per Requirement |
Marking |
Per Requirement |
Frequency Range |
1 - 500 MHz |
Impedance |
100 Ω |
Coupling Attenuation |
85 dB min @ 30-100 MHz 85-20 Log (f/100) @100-500 MHz |
Max. DC Resistance |
73 Ω/km @ 20 °C |
Max. Resistance Unbalance |
2 % |
Mutual Capacitance | 4.3nF/100m |
Capacitance Unbalance | 1.2 pF/m max. |
Velocity of Propagation | 78 % nom. |
Propagation Delay Skew | 25 ns/100m max. |
Dielectric Strength | 1.5 KV/minute |
Dielectric Strength to Shield | 1.5 KV/minute |
Min. Insulation Resistance | 5 GΩ•km |
Max. Tensile Strength - Short Term | 130 N |
Min. Bend Radius | 60 mm |
Operating Temperature Range | -20 °C +65 °C |
Cat. 6A Screened-pair Horizontal Cables*
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ACR dB |
ELFEXT dB |
PS.ACRF dB |
1 |
1.8 |
87.2 |
84.2 |
23.0 |
85.4 |
84.0 |
81.0 |
4 |
3.4 |
84.0 |
81.0 |
27.0 |
80.6 |
81.0 |
78.0 |
10 |
5.4 |
80.2 |
77.2 |
26.0 |
74.8 |
76.0 |
73.0 |
20 |
7.6 |
77.0 |
73.8 |
26.0 |
69.4 |
70.0 |
67.0 |
31.25 |
9.7 |
75.6 |
72.6 |
26.0 |
65.9 |
65.0 |
63.0 |
100 |
18.0 |
72.0 |
69.0 |
26.0 |
54.0 |
55.0 |
52.8 |
150 |
23.6 |
69.0 |
66.0 |
26.0 |
45.4 |
53.5 |
51.5 |
200 |
25.0 |
66.9 |
63.9 |
26.0 |
41.9 |
49.0 |
46.0 |
250 |
28.1 |
64.5 |
61.5 |
25.0 |
36.4 |
44.0 |
41.0 |
300 |
30.9 |
62.0 |
58.9 |
24.0 |
31.3 |
39.6 |
36.6 |
400 |
38.3 |
59.0 |
56.1 |
23.0 |
20.7 |
37.0 |
34.0 |
500 |
42.2 |
57.0 |
54.2 |
22.0 |
14.8 |
35.0 |
33.0 |
*Supplied cables meets Cat. 6a min. transmission requirements as per IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
114-10001504X |
Category 6A S/FTP 4 Pair Cable PVC |
305 mtr |
114-10002504X |
Category 6A S/FTP 4 Pair Cable LSZH |
305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)