Category 6A U/FTP 4 Pair Cable

Category 6A U/FTP 4 Pair Cable

Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m.Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. U/FTP (Foil Twisted Pair) cabling systems are installed for improved Alien Cross talk performance.  

Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m.Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. U/FTP (Foil Twisted Pair) cabling systems are installed for improved Alien Cross talk performance.  



PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material:

Bare Copper

Conductor Size:

0.57mm(D), 23 AWG

Conductor Construction:

Solid

Insulation Material:

SFS PE

Insulation O.D.:

1.36±0.05 mm

Conductor Unit Identification:

Solid/Stripe

Colour Code:

Per TIA/EIA 568-B

In. Shield Material:

Aluminium/Polyester Foil

In. Shield Design:

100% Coverage

Conductor Unit Lay-Up:

Pairs

Overall Drain-Wire Material:

N/A

Overall Drain-Wire size:

N/A

Overall Drain-Wire Construction:

N/A

Total Number of Wires:

8

Outer Jacket:

LS0H Halogen free flame retardant or PVC

Outer Jacket thickness & Ex. Diameter:

0.55±0.05mm, 7.5±0.5mm

Rip Cord:

Yes

Outer Jacket Colour:

Per Requirement

Marking:

Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Characteristic Impedance:

100Ω

Frequency Range:

1-500MHz

Coupling Attenuation:

55 dB min @ 30-100 MHz 55-20Log(f/100) @100-500 MHz

Max. DC Resistance:

73 Ω/km@20°C

Max. Resistance Unbalance:

2 %

Mutual Capacitance:

4.3nF/100m

Capacitance Unbalance:

1.2 pF/m max.

Velocity of Propagation:

78 % nom.

Propagation Delay Skew:

25 ns/100m max.

Dielectric Strength:

1.5K V/minute

Dielectric Strength to Shield:

1.5kV/minute

Min. Insulation Resistance :

5 GΩ•km

Max. Tensile Strength - Short Term:

130 N

Transfer Impedance:

10 m/m max @ 1-10 MHz 30 m/m max @ 30 MHz

Min. Bend Radius:

70 mm

Max. Operating Temperature:

+60 °C

Min. Operating Temperature:

-20 °C

Transfer Impedance:

50 m/m max @ 1 MHz, 100 m/m max @ 10 MHz.

200 m/m max @ 30 MHz,1000 m/m max @ 100 MHz.

TRANSMISSION PERFORMANCE

Cat. 6A Screened-pair Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ACR
dB
ELFEXT
dB
PS.ACRF
dB

1

1.8

87.0

84.0

23.0

85.2

84.0

81.0

4

3.4

85.0

83.0

27.0

81.6

81.0

78.0

10

5.4

77.3

74.3

26.0

71.9

76.0

73.0

20

7.6

70.0

67.0

26.0

62.4

70.0

67.0

31.25

9.7

68.0

65.0

26.0

58.3

65.0

63.0

100

18.0

65.3

62.3

26.0

47.3

55.0

52.8

150

23.6

62.0

59.0

26.0

38.4

53.5

51.5

200

25.0

59.0

57.2

26.0

34.0

49.0

46.0

250

28.1

57.6

54.6

25.0

29.5

44.0

41.0

300

30.9

55.0

52.0

24.0

24.1

39.6

36.6

400

38.3

53.0

51.8

23.0

14.9

37.0

34.0

500

42.2

52.0

50.0

22.0

9.8

35.0

33.0

*Supplied cables meets Cat. 6a min. transmission requirements as per IEC 61156-5 Ed. 2

Part Number Description Standard Length

114-10001304X

Category 6a U/FTP 4 Pair Cable PVC

305 mtr

114-10002304X

Category 6a U/FTP 4 Pair Cable LSZH

305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)