MTP/MPO TRUNK CABLES

Norden MTP/MPO Trunk & Fan-out trunk patch cords provide an efficient way to install a large number of cables quickly. It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance. MTP Trunk Cables are factory pre-terminated and available with OM3, OM4, & SM assemblies.

Norden MTP/MPO Trunk & Fan-out trunk patch cords provide an efficient way to install a large number of cables quickly. It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance. MTP Trunk Cables are factory pre-terminated and available with OM3, OM4, & SM assemblies. 

STANDARDS

  • EIA/TIA, Telecocordia GR-326-CORE Standards
  • TIA 605-4 (FOCIS 5)
  • IEC61754-7 

FEATURES

  • Easy to deploy - Factory-terminated systems can save installation and network reconfiguration time.
  • Reliability - use high-standard components to ensure product quality.
  • Factory terminated and tested
  • Allow easy migration from 10GbE to 40GbE or 100GbE
  • Ideal for 400G High-Speed Network connection 

MECHANICAL & ENVIRONMENTAL CHARACTERISTICS


Fibre Mode 

Single-mode: OS2 9/125µm

Multimode: OM3/OM4/OM5 50/125µm

Connector
MTP/MPO Standard & MTP/MPO PRO 
Connector Type
MTP -Male, Female; MPO-Male, Female
Polarity
Type A, Type B, Type C 
Breakout/fanout Connectors 
LC, SC, FC & Customized
Strength Member
Aramid Yarn
Length
Standard & Custom Lengths
Cable Jacket
PVC, LSZH, OFNP & OFNR
Operating Temperature
-20°C ~ 70°C
Storage Temperature 
-20°C ~ 70°C
Installation 
0°C ~ 50°C

Fibre Count 

812162436487296144

Pulling Eye OD (MTP)

191919191919353538


TRUNCK CABLE PHYSICAL CHARACTERISTICS


Fiber Count 
Cable Diameter
MAX Installation Tension(N) 
MAX Crush Resistance(N/dm) 
Minimum Bend Radius (mm) 


InstallationLong Term
8
3.0
20050020D
10D
123.0
20050020D
10D
243.0
20050020D
10D
367.5
600
100020D
10D
487.5
600
100020D
10D
728.4
600
1000
20D
10D
969.9600
1000
20D
10D
14412.06001000
20D
10D


MTP/MPO TRUNK CABLES


Performance Specifications Multi Mode System (OM3) Multi Mode System (OM4) Single Mode System (OS2)
Maximum Attenuation (dB/km)850 nm1300 nm
850 nm 1300 nm1310 nm1550 nm 

3.5 
1.53.5 1.50.360.21


MTP / MPO TERMINATION

Type Single-mode (APC polish) Single-mode (PC polish) Multi– mode (PC polish)
Fibre Count12,24,48,72,144 12,24,48,72,144 12,24,48,72,144
Fibre Type
G652D, G657A1, G657A2
G652D, G657A1, G657A2
62.5/125, OM2, OM3, OM4
Maximum Insertion Loss Ultra-Low Loss Standard Ultra-Low Loss
Standard Ultra-Low Loss
Standard

≤0.35 dB 0.25 dB Typical ≤0.70 dB 0.5 dB Typical ≤0.35 dB 0.25 dB Typical ≤0.70 dB 0.5 dB Typical ≤0.35 dB 0.2 dB Typical ≤0.7 dB 0.35 dB Typical
Return Loss ≥60 dB ≥50 dB ≥30 dB
Durability
≥200 times
≥200 times
≥200 times
Test Wavelength
1310 nm / 1550 nm
1310 nm / 1550 nm
850 nm / 1300 nm


MTP/MPO FAN-OUT HYDRA CABLE

MTP/MPO fanout/ breakout cable assembly with one MTP/MPO connector on one end and multiple single-fibre connectors (LC, SC, FC) on the other end, designed for data distribution and routing to patch panels. It is used to transition from trunk backbone assemblies to the fibre rack system. These cables are fully configurable and available with a variety of cable and connector combinations.


GENERIC CONNECTER TERMINATION

TypeSingle-mode (APC polish)Single-mode (PC polish)Multi– mode (PC polish)
Fibre Type
G652D, G657A1, G657A2
G652D, G657A1, G657A2
62.5/125, OM2, OM3, OM4
Maximum Insertion Loss Low LossStandardElite / Low LossStandardElite / Low LossStandard

≤0.1 dB 
≤0.30 dB≤0.2 dB≤0.30 dB≤ 0.2 dB ≤0.30 dB 

0.05 dB Typical
0.25 dB Typical
0/05 dB Typical
0.25 dB Typical
0.05 dB Typical
0.25 dB Typical
Return Loss≥60 dB≥50 dB≥30 dB
Durability
≥500 times
≥500 times
≥500 times
Test Wavelength
1310 nm / 1550 nm
1310 nm / 1550 nm
850 nm / 1300 nm