160-200kVA UPS DOUBLE CONVERSION TRANSFORMER-LESS

Norden's Ultra power series 160-200 kVA UPS is an online double conversion UPS that has three-phase in both input and output and a unity output power factor. This features a maximum parallel expanded operation of up to 6 units and has an inverter efficiency upto 96% makes it suitable for data center applications.

Norden's Ultra power series 160-200 kVA UPS is an online double conversion UPS that has three-phase in both input and output and a unity output power factor. This features a maximum parallel expanded operation of up to 6 units and has an inverter efficiency upto 96% makes it suitable for data center applications.

General Features

  • Wide input voltage range 140~485Vac  (Phase voltage 80~280Vac)
  • High input power factor, can be up to 0.99
  • Three-level inverter topology, the efficiency can be up to 96%
  • Support parallel expanded operation: maximum is 6 units Input current harmonic:<3%
  • Input current harmonic:<3%
  • Large charging current
  • High adaptability for the load it can connect full inductive load or capacitive load
  • Power Walk in function, it can reduce the star current impact to the system and reduce the capacity of the generator
  • Optimization battery group, the quantity of battery:30-50pcs
  • LBS function can realize 2 independent UPS systems work in synchronization enhancing the reliability of the system
  • The output factor is 1.0, and can be meet 100% unbalanced load
  • Support USB,RS485,RS232,SNMP,dry contact card


Specification


ModelCN933160U
CN933180U
CN933200U

Capacity

kVA

160

180200

Watts

160K

180K
200K

Input

Normal Voltage380/400/415Vac (3Ph+N+PE)
Operating voltage range
140~485Vac for 40% Load; 305~485Vac for Full Load
Harmonic distortion(THDi) 
<3%(100% linear load)
Operating frequency range
40~70Hz
Power factor
≥0.99 
Bypass voltage range

220Vac Max.Voltage:+25% (optional +10%,+15%,+20%) 230Vac Max.Voltage:+20%(optional +10%,+15%) 240Vac Max.Voltage:+15%(optional +10%) Min.Voltage:-45%(optional -20%,-30%)

Bypass Frequency range
Frequency synchronize tracing range:±10% 
Generator input
Support

Output

Rated voltage380/400/415Vac (3Ph+N+PE)
Power factor
0.9
Voltage regulation
±1%
Frequency    Line mode
±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional)
                              Frequency   Bat. mode
50/60(±0.1)Hz
Crest factor
3:1
Harmonic distortion (THDv)
≤2% with linear load, ≤4% with non-linear load
Efficiency
96%
Output Waveform
Pure Sine Wave

Battery

Rated voltage±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs)
Charging current (Charging current can be set according to the battery capacity installed)
   60A 
    80A

System Features

Transfer timeMains to battery:0ms; Mains to bypass:0ms
Overload  Line mode
≤110%: Overload 60min, ≤150%: Overload 1min, >150% turn to bypass mode immediately
Overload  Bypass mode135% Overload long time; 170% Overload 100ms
Backfeed Protection Support
Alarm
Overload, utility abnormal, UPS fault, battery low, etc
Protection
Short circuit, overload, over-temperature, battery low, fan fault alarm
Remote LCD
Support
Communication
USB, RS232, RS485, Parallel port,dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional)

Environment

Operating temperature0~40°C
Storage temperature
-25~55°C
Humidity range
0~95% (Non-condensing)
Altitude
<1500m
Noise level
<63dB
64
<66db

Physical

Dimension WxDxH(mm) 
850x442x1200                                         850x600x1600
Net Weight (kg)
200
220
280

Standards

SafetyIEC/EN62040-1,IEC/EN60950-1
EMC
IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 


Part NumberDescription
CN933160U160kVA Double Conversion Transformer-less 3/3 UPS (External Battery)
CN933160U-5L
160kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) 
 CN933180U
180kVA Double Conversion Transformer-less 3/3 UPS (External Battery)
CN933180U-5L
180kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) 
CN933200U200kVA Double Conversion Transformer-less 3/3 UPS (External Battery)
CN933200U-5L
200kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) 


COMPATIBLE ACCESSORIES

Part NumberDescription
CNS01 
SNMP Card for 10-80kVA 3/1 and 3/3